Monitor 506N3 VitalCare

VitalCareTM 506N3 series

Designed to travel everywhere you do, the VitalCareTM 506N3 series patient monitor with integrated carry-handle attaches quickly and easily to a rolling stand. Available in multiple configurations – with choice of Criticare or Nellcor oximetry – the 506N3 patient monitors provide maximum versatility and cost-effectiveness. New smart battery management allows up to 100 NIBP measurements on a single charging. With a compact design that is easily setup for spotcheck or continuous monitoring, the 506N3 patient monitor adapts readily to hospital, clinic and transport requirements.

Features and Benefits

  • Proprietary ComfortCuff ™ NIBP measures on inflation for faster, more comfortable readings.
  • Choice of Criticare DOX™ digital SpO2 technology or Nellcor OxiMax™ SpO2 technology.
  • Audible and visual alarms are adjustable providing instant notification the way you need them.
  • Optional FILAC FasTemp™ predictive temperature for quick, accurate measurements.
  • Optional internal printer for on-demand, automatic interval, trends or multi-patient reports.

Non-Invasive Blood Pressure

  • Technique: Oscillometric measure upon inflation
  • Measurement Time: <40 seconds typical; 0 to 300mmHg;
  • standard adult cuff
  • Automatic Measurement
  • Cycles: 1 - 60 minute; 2 - 4 hour; STAT
  • Inflation Pressure Range: 30 to 300mmHg (Adult)
  • 30 to 150mmHg (Pediatric)
  • 20 to 150mmHg (Neonate)
  • Resolution: 1mmHg
  • Clinical Accuracy: SP-10:2002
  • Transducer Accuracy: ±2mmHg or ±2% of reading, whichever is
  • greater, over full range
  • STAT mode: 5 minutes of consecutive readings

Pulse Oximetry

  • Range: 1% to 99%
  • Resolution: 1%
  • Accuracy (DOX only): 70% to 99% range: ±2%;
  • 50% to 69% range: ±3%;
  • <50%: unspecified
  • Accuracy (OxiMax Only): 70% to 99% range: ±2%;
  • <70%: unspecified
  • Method: Dual wavelength LED
  • Audio: Tone with each detected pulse; pitch varies with saturation

Heart (Pulse) Rate

  • Range: 20 to 300bpm
  • Accuracy (DOX only): Greater of ±1bpm or ±1%, of reading
  • Unspecified for <30 or >240 bpm
  • Accuracy (OxiMax only): Greater of ±1bpm or ±1%, of reading
  • Unspecified for <30 or >240 bpm
  • Update Time: Every second
  • Resolution: 1bpm
  • Pulse Volume: 10 levels or Off

Temperature (optional)

  • Type: FILAC FasTemp™
  • Method: Predictive or Continuous
  • Channels: 1
  • Range: 30.0º to 43.0º C
  • Accuracy Continuous Mode:±0.2°F (±0.1°C)
  • Accuracy Predictive Mode: ±0.2°F (±0.1°C) for ranges 37°C to 39 °C
  • (Compliant with EN 12470-3 and
  • ASTM E1112:98)
  • Resolution: 0.1º F or 0.1º C
  • Predictive Response Time: Oral: 10 seconds typical;
  • Axial: 10 seconds typical;
  • Rectal: 10 seconds typical
  • Probes/Wells: Oral/Axial FILAC FasTemp [202026]
  • Rectal FILAC FasTemp (optional) [202034]
  • Isolation Well, Oral, Axial [202089]
  • Isolation Well, Rectal (optional) [202087]

Alarms

  • Indication: Audible; Visual
  • Volume: 10 levels or Off
  • Silence: Yes; 2 minutes or permanent

Mechanical

  • Weight: Base unit with battery: 6.95 lb; 3.15kg
  • Size: Base unit: 8.7" (H) x 7.1" (W) x 6.5” (D); 22cm (H) x 18cm (W) x 16.5cm (D)

Power Requirements

  • Voltage: 100 to 240 VAC, 50 to 60 Hz
  • Battery: Sealed lead acid; Life: 8 hours
  • Rechargeable: 6 hours

Environmental

  • Operating Temperature: 32º to 113º F; 0º to 45º C
  • Storage Temperature: 23º to 122º F; -5º to 50º C
  • Operating Humidity: 15% to 90%, non-condensing

Classification

  • Type of Protection: Class I equipment
  • Degree of Protection: Type CF defibrillator-proof equipment
  • Protection against Ingress: IPX1 rating, Drip-Proof Equipment