Размер: A A A Интервал: АБ Цвета: A A A A Изображения: Включить графику Выключить графику
Обычная версия
Go to top

Syringe Pump

Syringe pump Byond BYZ-810

Syringe pump Byond BYZ-810

Single Channel Syringe Pump 

  • HD LCD Display, high capacity words, friendly user interface, dynamically display working status;
  • Audible and visual alarm for occlusion, empty, near empty, low battery, end of infusion, syringe loose, wrong setting, etc.;
  • Compatible with 5ml, 10ml, 20ml, 30ml, 50/60ml syringe of any brands;
  • Preset solution volume to greatly reduce the workload of nurses;
  • Three working modes: Rate mode, Time Volume mode, Dosage Weight mode;
  • Three levels of occlusion: high, medium and low;
  • Purge and Bolus function;
  • KVO (keep-vein-open) automatically opens as injection is completed, KVO rate is 0.1-5ml/h(0.1ml/h step);
  • Freely Stackable: freely stack one syringe pump onto another to provide multiple solutions, which have a wide range of clinical applications;
  • Power Source: AC100---240V, 50/60Hz; Internal Battery, DC12V car charge;
  • One-key operation makes setup easy and simple;
  • Syringe plunger grabble detector, operable with one hand in a No-Germ Environment;
  • Automatically record the settings of last injection;
Model BYZ-810
Unique Human Voice Alarm system  The device triggered the human voice prompt and stop injection automatically when there is any malfunction, making the infusion process safer and more reliable. 
Rate:  50/60ml Syringe: 0.1ml/h ~ 999.9ml/h (0.1ml/h step) 
1,000ml/h ~ 1,500ml/h (1ml/h step) 
30ml Syringe: 0.1ml/h ~ 900.0ml/h (0.1ml/h step) 
20ml Syringe: 0.1ml/h ~ 600.0ml/h (0.1ml/h step) 
10ml Syringe: 0.1ml/h ~ 300.0ml/h (0.1ml/h step) 
Flow Rate Accuracy  Within ±3% (after correct calibration) 
Mechanical precision  Within ±2% 
Bolus Rate  50/60ml Syringe: 1,200ml/h 
30 ml Syringe: 720ml/h 
20 ml Syringe: 480ml/h 
10 ml Syringe: 240ml/h 
Purge Rate  50/60ml Syringe: 1,500ml/h 
30ml Syringe: 900ml/h 
20ml Syringe: 600ml/h 
10ml Syringe: 300ml/h 
Volume Limit  0.1ml ~ 9999.9ml (0.1ml step) 
Total Injection 
Volume 
0.1ml ~ 9999.9ml (0.1ml step) 
Occlusion of Single Channel Syringe Pump  High: 800mmHg ±200mmHg (106.7kPa±26.7kPa) 
Medium: 50/600mmHg ±100mmHg (66.7kPa±13.3kPa) 
Low: 300mmHg ±100mmHg (40.7kPa±13.3kPa ) 
Alarms  Injection soon finish, end of injection,occlusion, improperly installation of syringe, wrong setting, low battery, syringe loose etc.
Power Source  AC 100V ~ 240V, 50/60Hz; Internal rechargeable Li battery, capacity≥1,600mAh, 4 hours internal battery backup 
KVO rate  1ml/h 
Fuse  F1AL/250/60V, 2pcs inside 
Power Consumption  30VA 
IP Classification  IPX4 
Equipment Classification  Class II, internal power supply, Type CF 
Operating Condition  Ambient temperature: +5℃~ +40℃ 
Relative humidity  20 ~ 90% 
Transport & Storage Condition  Ambient temperature:-30℃~ +55℃ 
Relative humidity  ≤95% 
Dimension  280mm (L) ×210mm(W) ×130mm(H) 
Weight  2.2kg (net weight) 
LinkLanguageSize
Registration certificateRussian6 мбpdf
User's manualRussian2,5 мбdoc
You can request additional information about the equipment, as well as find out the cost and place an order by writing to us at info@westmedgroup.ru

Infusion Pump Byond BYS-820

Infusion Pump Byond BYS-820
  • HD LCD Display, high capacity words, friendly user interface, dynamically display working status;
  • Audible and visual alarm for occlusion, empty, low battery, end of infusion, door open, wrong setting, etc., which gain patents;
  • Compatible with any brands of infusion sets after correct calibration;
  • Preset solution volume to greatly reduce the workload of nurses;
  • Work mode: ml/h and drop/min can switch freely;
  • Three levels of occlusion: high, middle and low;
  • Purge function;
  • KVO (keep-vein-open) automatically opens as infusion is completed, KVO rate is 1-5ml/h(1ml/h step);
  • Power Source: AC100---240V, 50/60Hz; Internal Battery;
  • Automatically record the settings of last infusion;
Rate  1 ml/h ~ 1,200 ml/h 
Flow Rate Accuracy  Within ±5% (after correct calibration) 
Mechanical precision  Within ±2% 
Purge Rate  100 ml/h ~ 1,000 ml/h (100 ml/h step) 
Infusion Volume  1 ml ~ 9999 ml 
Total Infusion Volume  0.1 ml ~ 9999.9 ml 
KVO rate  1 ml/h ~ 5 ml/h (1 ml/h step) 
Occlusion  High: 800 mmHg ±200 mmHg (106.7 kpa±26.7 kpa 
Medium: 500 mmHg ±100 mmHg(66.7 kpa±13.3 kpa 
Low: 300 mmHg ±100 mmHg (40.7 kpa±13.3 kpa ) 
Unique audible and visible alarm  Human voice alarm for End of injection, occlusion, door open, bubbles in the tube, wrong setting, low battery, AC power pulled out etc. 
Power Source  AC 100V ~ 240V, 50/60Hz; Internal rechargeable Li battery, capacity≥1,600mAh, 4 hours internal battery backup 
Bubble detector  Ultrasonic wave detector; detection sensitivity ≥25μL 
Power Consumption  18VA 
Operating Condition  Ambient temperature: +5℃ ~ +40℃; 
Relative humidity: 20 ~ 90% 
Atmospheric pressure: 86.0 kpa ~ 106.0 kpa 
Transport & Storage Condition  Ambient temperature:-30℃ ~ +55℃ 
Relative humidity: ≤95% 
Equipment Classification  Class II, internal power supply, Type CF 
IP Classification  IPX4 
Dimension  140 mm (L) ×157 mm(W) ×220 mm(H) 
Weight  1.8 kg (net weight) 
LinkLanguageSize
Registration certificateRussian6 мбpdf
User's manualRussian650 кбdoc
You can request additional information about the equipment, as well as find out the cost and place an order by writing to us at info@westmedgroup.ru

Write answer 2 + 2 =

By clicking the "Send request" button, you consent to the processing of your personal data. Privacy Policy
Thansk!

Your message has been sent.